1. Common Non-Destructive Testing Methods
Ultrasonic Testing (UT): The core method, accurately detecting internal defects such as folds, delamination, inclusions, and porosity. By analyzing the location and amplitude of the echo signal, the depth, size, and distribution of defects are determined.
Radiographic Testing (RT): Utilizes X-ray or gamma-ray imaging to identify volumetric defects such as porosity and inclusions, suitable for critical parts of thick-walled tubes.
Eddy Current Testing (ET): Quickly screens for conductive material defects such as surface and near-surface cracks and pinholes, suitable for online inspection.
Magnetic Particle Testing (MT): Used for ferromagnetic materials, revealing surface cracks and folds through magnetic traces; simple to operate but limited to surface testing.
2. Defect Judgment Criteria
Folds, Delamination, and Inclusions: In ultrasonic testing, these manifest as continuous or intermittent reflected waves, located inside the tube wall, and cannot be eliminated by grinding; the tube must be scrapped.
Penetrating Cracks and Porosity: Regardless of size, once a crack penetrates the pipe wall or forms a continuous channel, it is considered irreparable and welding repair is strictly prohibited.
Severe Wall Thickness Inconsistency and Bulging: If the measured wall thickness deviation exceeds the standard allowable range (e.g., ±12.5% as specified in GB/T 8162), or if there is localized expansion that cannot be corrected, the pipe should be rejected immediately.
Deep Scratches (>30μm): These can easily cause fatigue fracture in high-pressure systems; even if they do not penetrate, the pipe should be replaced.
3. Recommended Inspection Process
Preliminary Visual Inspection: Observe the surface for obvious cracks, bulges, severe folds, etc.
Dimensional Measurement: Use an ultrasonic thickness gauge to check the uniformity of wall thickness.
Non-Destructive Testing: Ultrasonic + eddy current combined testing is preferred to cover both internal and external defects.
Result judgment: According to standards such as GB/T 5777-2017 and GB/T 8163-2023, any defects involving damage to structural integrity shall not be repaired and the entire structure shall be discarded.